Our hospital values employee and patient safety. This is why the importance of sterilization and infection control is great. Infection control; modern devices and current sterilization information are carried out under light.
In our central sterilization system, we believe that the right record for patient and employee safety will be the correct evidence. In our cen- tral sterilization system, which sterilization information is available to which patient, which device is used retrospectively.
In our central sterilization unit, daily sterilization criteria;
Bowie-Dick test application
use of biological and chemical indicators
the device output filings of the autoclaves sterilization process are taken and filed.
Central Sterilization Unit According to Service Quality Standards
Dirty area
Clean area
sterile field.
Our Hospital Central Sterilization Unit;
Three double-door autoclaves,
Four double-door washer disinfector devices,
Four cassette type autoclaves,
Pneumatic (carrier) system
Head lubrication devices are available.
In central sterilization process;
Dirty instruments are counted and the unit name and clinical name information are recorded in the HBYS Sterilization Module.
Dirty area dirty tools are washed and mechanically cleaned. The instruments are then placed in a double-door washer-disinfector. Dirty tools are cleaned in the washing disinfector device and then taken out from the clean outlet door which is in the clean area in dry state, and are passed to packaging stage.
Clean instruments are packaged by forming treatment and examination sets according to treatment procedures. Packaged instruments are barcoded separately in the direction of the information recorded in the dirty entrance.
On the barcode;
Physician name,
Clinical name,
Date of packaging,
Expiration date,
The sterilization device,
Sterilization person information is included.
Packaged tools, double-door autoclave is placed on the clean side. After sterilization, the instruments are removed from the autoclave and placed on specially prepared shelves.
The instruments stored in the sterile field are recorded by reading the barcodes via the HBYS Sterilization Module and transferred to the relevant physicians and clinics.
The aerators, micromotors, gymnastics, etc. to be sterilized are sent to the Central Sterilization Unit via the pneumatic (carrier) system located on the floors of the hospital with dirty tool carrier capsules.
Codified headers are recorded on HBS Sterilization Module and packed after central lubrication washing process and sterilized by barcoding.
Sterilization processes are completed by reading the barcodes, and the output information is saved on HBYS. The relevant physician and clinic are sent via pneumatic (carrier) system with clean instrument carrier capsules.